• Call Us : (+91) 1126274531
  • Mobile No.: (+91) 7065-200-338
  • sales@neutech.co.in

Our Services


Neutech is recognized in providing best support in electrical, cooling and BMS system Installation to carry out turn-key Project works or alternatively work as sub-contractors where Clients require this arrangement. Neutech offer a wide range of installation services as per Industrial sector and client requirement.

Our services in -

Electrical

  • Electrical Panel
  • Transformers
  • Building management system
  • IBMS
  • Access control system
  • IP CCTV & Access Control
  • Gas based suppression system
  • WLD & VESDA System
  • Intrusion Detection System (IDS)
  • UPS
  • Air Conditioning (CAC & PAC)

Condition Based Monitoring & Technical Audits

  • Power Audit- quality of power
  • Air quality
  • Thermography
  • Harmonic Analysis Study
  • Vibration Analysis
  • Energy Audit & Energy Efficiency Assessment
  • Air balance monitoring
  • Infrastructure condition and capacity assessment
  • Risk assessment on Equipment & Processes and Failure Mode Effect Analysis
  • Thermal comprehensive assessment
  • Relay testing

Description

Electrical: ( Installation and Commissioning )

  • High Voltage power reticulation
  • Low & medium voltage industrial panel
  • Transformer and Diesel Generator
  • Earth pit construction and testing
  • UPS and battery bank installation
  • Hazardous Areas electrical installations
  • Instrumentation installation & commissioning
  • Data & communications cable installations
  • Switchboard supply & installation
  • Power Quality metering installation

Electrical Panel


  • AHU Panel
  • PCC Panel
  • LT Panel
  • HT Panel
  • PLC Panel
  • Desktop Panel
  • Capacitor Panel

Transformers


  • Oil Filled Distribution Transformer
  • BIS ISI Marked Transformer
  • BEE Star Labelled Transformer
  • Eco-Smart Efficient Transformer
  • OLTC Transformer
  • 3, 4 & 5 Winding Transformer
  • Special Duty Transformer
  • Step Up Transformer
  • Furnace Transformer
  • Servo Voltage Stablizer
  • Compact Unitized Sub Station
  • Transformer Repair & Service

Building management system


  • Supervisory, Control and Data Acquisition (SCADA)
  • Programmable Logic Controllers (PLC)
  • Energy Management System (EMS)
  • Data gathering panels (DGP)
  • Modbus, Lon works, and Bacnet – All refer to communications protocols – 'Front End' – legacy term used to refer to the BMS Operator Workstation

IBMS


Intelligent Building Management SystemBuilding Management System (BMS) is a computer based control system installed in buildings that controls and monitors the building’s mechanical and electrical equipment such as air handling and cooling plant systems, lighting, power systems, fire systems, and security systems.


Access control system


  • Discretionary Access Control (DAC)
  • Mandatory Access Control (MAC)
  • Role-Based Access Control (RBAC)

Gas based suppression system


  • FM-200 Clean Agent Fire Suppression System.
  • Novec 1230 Clean Agent Fire Suppression System.
  • INERGEN Clean Agent Fire Suppression System.

SMPS


  • D.C. to D.C. Converter
  • Forward Converter
  • Flyback Converter
  • Self-Oscillating Flyback Converter

WLD & VESDA System


WLD system consists of water leak detector, sensor cable and wld panel. Water leak detection system provides an effective environment monitoring solution for problems related to water leak in data, server & computer rooms.

VESDA Systems are aspirating smoke detection used for early warning applications where response to a fire is critical. VESDA® works by continually drawing air into the pipe network via a high efficiency aspirator. A sample of this air is then passed through a dual stage filter.


Gas Suppression


Gas fire suppression systems are ideal for protecting assets where water may pose a risk. IT, Data and Communication areas are the most common risk applications.


IP CCTV & Access Control


Support Security and monitoring services. From basic security systems including CCTV, intruder alarms, barrier access to monitoring services.


Intrusion Detection System (IDS)


An Intrusion Detection System (IDS) is a system that monitors network traffic for suspicious activity and issues alerts when such activity is discovered. It is a software application that scans a network or a system for harmful activity or policy breaching. Any malicious venture or violation is normally reported either to an administrator or collected centrally using a security information and event management (SIEM) system. A SIEM system integrates outputs from multiple sources and uses alarm filtering techniques to differentiate malicious activity from false alarms.

Although intrusion detection systems monitor networks for potentially malicious activity, they are also disposed to false alarms. Hence, organizations need to fine-tune their IDS products when they first install them. It means properly setting up the intrusion detection systems to recognize what normal traffic on the network looks like as compared to malicious activity.

Intrusion prevention systems also monitor network packets inbound the system to check the malicious activities involved in it and at once sends the warning notifications.


Classification of Intrusion Detection System - IDS is basically classified into 2 types:

  • Network Intrusion Detection System (NIDS)
  • Host Intrusion Detection System (HIDS)

Detection Method of IDS:

  • Signature-based Method
  • Anomaly-based Method

UPS


  • Air Conditioning (CAC & PAC)

Condition Based Monitoring & Technical Audits


  • Power Audit- quality of power
  • Air quality
  • Thermography
  • Harmonic Analysis Study
  • Vibration Analysis
  • Energy Audit & Energy Efficiency Assessment
  • Air balance monitoring
  • Infrastructure condition and capacity assessment
  • Risk assessment on Equipment & Processes and Failure Mode Effect Analysis
  • Thermal comprehensive assessment
  • Relay testing